1. Common RO System Problems and Solutions
1.1 Low Water Production
Possible Causes:
- Low feed water pressure
- RO membrane fouling or scaling
- Low water temperature
- Blocked cartridge filters
Solutions:
- Check feed pressure and pump operation.
- Inspect and replace clogged filter cartridges.
- Check membrane performance and clean when necessary.
2.2 High Permeate Conductivity
Possible Causes:
- RO membrane damage or oxidation
- Improper operating pressure
- Damaged O-rings or seals
- Changes in feed water quality
Solutions:
- Check feed and permeate conductivity.
- Inspect membrane seals and connections.
- Verify operating conditions and membrane integrity.