Common RO Water Treatment System Problems and Solutions

Nov 07, 2026

Leave a message

1. Common RO System Problems and Solutions

1.1 Low Water Production

Possible Causes:
- Low feed water pressure
- RO membrane fouling or scaling
- Low water temperature
- Blocked cartridge filters

Solutions:
- Check feed pressure and pump operation.
- Inspect and replace clogged filter cartridges.
- Check membrane performance and clean when necessary.

2.2 High Permeate Conductivity

Possible Causes:
- RO membrane damage or oxidation
- Improper operating pressure
- Damaged O-rings or seals
- Changes in feed water quality

Solutions:
- Check feed and permeate conductivity.
- Inspect membrane seals and connections.
- Verify operating conditions and membrane integrity.