8040 RO Membrane

8040 RO Membrane

RAUSCHERT TF8040-SW belongs to the 8040 RO membrane format. For procurement or replacement, verify the element dimensions, active area, permeate tube and interconnector arrangement. The supplied datasheet lists a length of approximately 1,016 mm, a diameter of about 201 mm and an active area of 400 ft² (37.2 m²). Before installing it in an existing plant, check the pressure vessel, end connections and operating envelope instead of relying on the 8040 label alone.
Send Inquiry
Description
Technical Parameters

Fujian Huamo Technology Co., Ltd. is one of the most reliable manufacturers and suppliers of 8040 ro membrane in China. If you're going to wholesale bulk 8040 ro membrane made in China, welcome to get catalog and price list from our factory. All custom made products are with high quality and competitive price. Also, OEM service is available.

 

1. Product Details 

8040 is a common industrial element-size designation, but products sharing this label may differ in active area, permeate tube, seal arrangement and performance curves. For replacement, compare the original equipment BOM, vessel documentation and removed element model, then verify adapters and connections. Standardized dimensions have supported modular plant design and maintenance procurement, but common size does not guarantee direct performance interchangeability between brands or series. Recalculate the array where necessary.

8040 Seawater RO Membrane

2. Product Parameters

Model

RAUSCHERT TF8040-SW

Element format

8040; nominal 8 in × 40 in / 8040

Active membrane area

400 ft² (37.2 m²)

Permeate flow

9,000 GPD (34.1 m³/d); individual elements may vary ±15%

Stabilized salt rejection

99.6%

Minimum salt rejection

99.4%

Boron rejection

93% (test feed boron 5 ppm)

Test conditions

32,000 ppm NaCl; 25°C; 800 psi (55 bar); pH 8; 8% recovery

Dimensions and weight

Length 1,016 mm (40 in); diameter 200 mm (7.9 in); tube 28.6 mm (1.125 in); 16 kg (35 lb) 

Operating limits

Max pressure 1,200 psi (82.7 bar); max temp 45°C; chlorine <0.1 ppm; continuous pH 2–11; cleaning pH 2–13; turbidity ≤1.0 NTU; SDI15 ≤5; max feed 75 gpm (17 m³/h); min concentrate:permeate 5:1; max element ΔP 15 psi (1.0 bar) 

Note:Performance figures are based on the uploaded datasheet and its stated test conditions. Confirm the current revision before publication.

3. Product Advantages and Features

8040 dimensional information is useful for spare-parts control. Maintenance teams can record model, length, diameter, active area and connection details, then compare them with existing system documents before ordering. If an old label is unreadable, photograph the end connection, permeate tube and vessel nameplate for supplier review instead of ordering by appearance. This lowers the risk of incorrect purchases, installation problems and avoidable downtime.

4. Company Profile

HUAMO product pages should connect model identification, dimensions, technical documents and the inquiry process. A buyer searching for an 8040 RO membrane can first confirm the size, then review seawater suitability and performance data. For project inquiries, collect feed TDS or salinity, temperature, required permeate flow, target TDS, power conditions and intended use. These inputs reduce unnecessary clarification, while lead time, certificates and warranty terms must still be confirmed for each order.

5. Company Advantages

Model control should record brand, series, format and full model separately. Keeping TF8040-SW in inquiry and order documents reduces confusion with other 8040 elements. Product images, labels, quotations and packing lists should use the same model spelling. When a product version changes, replace outdated datasheets and retain the revision date so customers do not design from obsolete figures.

6. FAQ

Q: Can every 8040 element be used as a direct replacement?

A: Not based on size alone. Verify active area, permeate tube, connectors, seals, pressure vessel and performance curve.

Q: What are the element dimensions?

A: The bulletin lists an approximate length of 1,016 mm, outside diameter of 201 mm and a 1.125 in (28.6 mm) permeate tube. Confirm the drawing before ordering.

7. Seawater Treatment Process

 For a retrofit, first confirm the intake and pretreatment capacity, then check the high-pressure pump, vessels, permeate piping and concentrate discharge. Before replacement, inspect cartridge filters, antiscalant arrangements, instrument calibration and vessel condition. After installation, restore design conditions gradually and record flow, conductivity and differential pressure to avoid hydraulic shock caused by incorrect pump or valve operation.

8. Export Packing and Transportation

English: For spares or small orders, compare courier, air freight and sea freight based on weight, urgency and destination. Courier can simplify door-to-door delivery; air freight may suit time-sensitive shipments; sea freight is often more suitable for larger quantities but takes longer. Choose according to the buyer's import capability, customs arrangements and delivery terms. Provide package dimensions, gross/net weight and a document list before dispatch.

9. Maintenance and Spare Parts

Before cleaning, identify the likely foulant and check pretreatment, antiscalant dosing, pressure control and recovery changes. Fully dissolve and mix cleaning chemicals before circulation. After cleaning, flush with suitable chlorine-free water and begin at reduced pressure and flow to remove residual solution before returning to normal conditions. Divert permeate for at least 30 minutes after cleaning, or until it is clear, while following the full supplier procedure and safety instructions.