Seawater Reverse Osmosis Membrane

Seawater Reverse Osmosis Membrane

RAUSCHERT TF8040-SW is a seawater reverse osmosis membrane element. Pressure drives water through a selective membrane layer while limiting the passage of most dissolved salts. The element is not a complete treatment plant; it must operate with suitable pretreatment, feed-pressure control, concentrate discharge and permeate collection. Engineers should establish array design, recovery and pressure from a feedwater analysis and the required product-water quality, while allowing for startup, flushing and cleaning procedures.
Send Inquiry
Description
Technical Parameters

Fujian Huamo Technology Co., Ltd. is one of the most reliable manufacturers and suppliers of seawater reverse osmosis membrane in China. If you're going to wholesale bulk seawater reverse osmosis membrane made in China, welcome to get catalog and price list from our factory. All custom made products are with high quality and competitive price. Also, OEM service is available.

 

1. Product Details 

Reverse osmosis uses a pressure difference to move water through a selective membrane layer while restricting the passage of salts and other dissolved constituents. Feed pretreatment must match the membrane and water chemistry; suspended solids, colloids, scaling potential and biological growth can affect operation. The datasheet limits for SDI, turbidity, residual chlorine and pressure drop should be included in the design review. Startup and cleaning must follow the supplier's full instructions to avoid hydraulic shock, permeate-side backpressure or chemical incompatibility.

Seawater RO Membrane

2. Product Parameters

Model

RAUSCHERT TF8040-SW

Element format

8040; nominal 8 in × 40 in

Active membrane area

400 ft² (37.2 m²)

Permeate flow

9,000 GPD (34.1 m³/d); individual elements may vary ±15%

Stabilized salt rejection

99.6%

Minimum salt rejection

99.4%

Boron rejection

93% (test feed boron 5 ppm)

Test conditions

32,000 ppm NaCl; 25°C; 800 psi (55 bar); pH 8; 8% recovery

Dimensions and weight

Length 1,016 mm (40 in); diameter 200 mm (7.9 in); tube 28.6 mm (1.125 in); 16 kg (35 lb) 

Operating limits

Max pressure 1,200 psi (82.7 bar); max temp 45°C; chlorine <0.1 ppm; continuous pH 2–11; cleaning pH 2–13; turbidity ≤1.0 NTU; SDI15 ≤5; max feed 75 gpm (17 m³/h); min concentrate:permeate 5:1; max element ΔP 15 psi (1.0 bar) 

Note:Performance figures are based on the uploaded datasheet and its stated test conditions. Confirm the current revision before publication.

3. Product Advantages and Features

Membrane performance depends on pretreatment, so confirming SDI, turbidity, residual chlorine and cleaning provisions during design reduces later uncertainty. For system integrators, early confirmation of feedwater and monitoring points helps define filtration, dosing, instrumentation and CIP arrangements. The product should not be described as maintenance-free; suitable pretreatment and monitoring remain necessary for sustained operation.

Seawater RO Membrane Packing

4. Company Profile

Fujian Huamo Technology Co., Ltd. supplies water-treatment membrane and system-related products. The company section on this seawater reverse osmosis membrane page should focus on product supply, technical-document communication and review of project parameters rather than generic slogans. Customers can submit a feed analysis and process diagram for discussion of the element model, operating envelope and items requiring further calculation. Public statements about manufacturing, certificates and references should be limited to evidence currently available.

4040 Seawater RO Membrane Factory Picture

5. Company Advantages

Technical sales translates the customer's intended result into verifiable engineering conditions. Confirm feedwater, target permeate, design flow and operating environment before discussing the element and complete-system scope. If a parameter is not supported by the available documentation, mark it for technical confirmation instead of filling the gap with marketing language. This improves the practicality of the quotation.

RO Membrane

6. FAQ 

Q: Can pretreatment be omitted?

A: It is not recommended. Pretreatment controls suspended solids, colloids, scaling and fouling risks and must be designed from the feed analysis.

Q: Does the element remove all dissolved gases?

A: No such claim is supported. The supplied document describes RO membrane performance and does not substantiate complete dissolved-gas removal.

7. Seawater Treatment Process 

RO design should treat pretreatment and membrane separation as linked stages. Pretreatment quality influences fouling risk, while RO operating conditions affect flow and salt passage. Provide procedures and connections for flushing, shutdown preservation and chemical cleaning. Disinfection, remineralization or further polishing depends on end use and cannot be determined from the element rejection figure alone.

8040 Seawater RO Membrane real picture

8. Export Packing and Transportation

For project orders, list element model, quantity, package count and related accessories separately on the packing list, keeping it consistent with the commercial invoice, transport documents and purchase order. If a certificate of origin, test record or other compliance document is required, confirm availability when placing the order. All documents must reflect the actual goods; do not make broad certificate or inspection claims merely for SEO purposes.

9. Maintenance and Spare Parts

A spare-parts plan may include matching membrane elements, seals, connectors, pressure gauges, conductivity instruments, pretreatment cartridges and cleaning consumables, depending on the actual plant. Record each replacement model, serial or batch information, service hours and failure cause to identify recurring fouling or equipment issues. Confirm dimensions, material compatibility and system interfaces before ordering; do not rely on the product name alone.