Fujian Huamo Technology Co., Ltd. is one of the most reliable manufacturers and suppliers of 8040 low pressure ro membrane in China. If you're going to wholesale bulk 8040 low pressure ro membrane made in China, welcome to get catalog and price list from our factory. All custom made products are with high quality and competitive price. Also, OEM service is available.
Product Details
8040 low pressure RO membrane achieves efficient desalination even at lower operating pressures, thereby significantly reducing energy costs for commercial water treatment systems. 8 inch RO membrane is an ideal choice for tap water purification and water treatment in large-scale commercial and industrial systems-such as boiler feed water, reclaimed water reuse, and large-scale purified water plants.
Video Description
This is one of our warehouses used to store finished reverse osmosis membranes. There is high demand for 8040 low pressure RO membrane in the international market. Located within our headquarters and production facility in Quanzhou, Fujian, this warehouse covers an area of 1,000 square meters and maintains ample inventory of finished products. For small orders, we can ship immediately upon receipt of payment, ensuring a positive shopping experience for you.
Product Specifications
Model | Reverse Osmosis Membrane ULP8040 |
Permeate Flow Rate | 12100 Gallons /Day (45.7 m³/day) |
Stabilized Salt Rejection | 99.3% |
Maximum Pressure Drop per Element | 1.0 bar (15 psi) |
Maximum Operating Pressure | 41 bar(600 psi) |
Factory Location | Quanzhou City, Fujian Province |
Delivery Time | Depends on the quantity |
Active Membrane Area ft2(m2) | 400(37) |
Stabilized Salt Rejection % | 99.3 |
Minimum Salt Rejection % | 99 |
Permeate Flow Rate gpd(m3 /d) | 12100(45.7) |
- Test Condition: Feed Water Pressure 1.03MPa (150 psi);
- Feed Water Temperature: 25 °C (77 °F);
- Feed Water Concentration 1,500 ppm NaCl;
- Feed Water pH: 8; Permeate Recovery 15%
Our Service
- We are an experienced Reverse Osmosis Membrane factory in China with comprehensive qualifications.
- We offer a wide variety of reverse osmosis membranes for you to choose from.
- We can print your exclusive logo on the labels of the reverse osmosis membrane elements.
- We provide OEM and ODM manufacturing services, we have received a number of inquiries from customers about the 8040 low pressure RO membrane


Our Advantages
Longstanding Legacy: Established 20 years ago, our company has been recognized as one of only three "Demonstration Bases for China's Reverse Osmosis Membrane Industry." We are committed to providing you with premium quality at highly competitive prices.
Customization on Demand: We manufacture products tailored specifically to our clients' requirements, ensuring that their needs are met at any time.
Integrity in Business: Our company has established long-term and stable cooperative relationships with numerous manufacturers overseas, including those in Turkey, Uzbekistan, Germany, Mexico, the United States, Kenya, Indonesia, Vietnam, and others.



FAQ
Q: What are the key differences between the 8040 low-pressure reverse osmosis membrane and standard membranes?
A:Lower Operating Pressure: For the same water production volume, low-pressure membranes typically require an inlet pressure that is 20%–30% lower than that of standard membranes (e.g., while standard membranes require 1.5–2.0 MPa, low-pressure membranes require only 1.0–1.5 MPa).
Significant Energy-Saving Advantages: They reduce the energy consumption of high-pressure pumps, making them ideal for large-scale water treatment systems (such as reclaimed water reuse and boiler feedwater applications).
Comparable Desalination Rates: Low-pressure membranes still achieve a stable desalination rate of over 99.3%
Applicable Scenarios: Projects involving feed water with low salinity levels (such as tap water or surface water) and those where operating electricity costs are a critical consideration.
Q: Do low-pressure membranes impose stricter requirements on feed water quality?
A: The SDI (Silt Density Index) must still remain below 5, with some applications requiring it to be below 3 (consistent with standard membranes).
Tolerance levels for residual chlorine, temperature, and pH are essentially the same as those for standard membranes (pH range: 2–11; residual chlorine: <0.1 mg/L).
Low-pressure membranes are more susceptible to fouling by organic matter and microorganisms, as their surface charge and roughness may have been optimized for low-pressure operation; consequently, enhanced pretreatment is required.
Recommendation: Install a guard filter (filtration rating ≤5 μm) and regularly monitor the ORP (Oxidation-Reduction Potential).
Q: Does the cleaning cycle for low-pressure membranes differ from that of standard membranes?
A: The cleaning frequency is higher (approximately once every 1–3 months, whereas standard membranes can go 3–6 months), as the surface of low-pressure membranes is more prone to adsorbing low-molecular-weight organic substances.
Recommended Cleaning Methods:
Acidic cleaning (pH 2–3, using citric acid or HCl) to remove inorganic scaling.
Alkaline cleaning (pH 11–12, using NaOH + EDTA) to remove organic matter and microorganisms.
Note: Avoid using strong oxidizing agents (such as sodium hypochlorite), as they will damage the polyamide layer of the membrane.





